MUN12AD01-SG · 1 A Non-Isolated Step-Down Power Module, 0.8-6 V Output
MUN12AD01-SG is a non-isolated 1 A point-of-load step-down module in a 6-LDFN package. The listing shows 0.8-6 V output, 94% efficiency, remote on/off, OCP, OTP and UVLO. It is not an isolated converter. Because the page lists 4.5 V input without a complete range, confirm input limits, output setting, external components and thermal derating from the exact datasheet.

| Part number | MUN12AD01-SG |
| Manufacturer | Delta |
| Description | 1 A Non-Isolated Step-Down Power Module, 0.8-6 V Output |
| Package | 6-LDFN Module |
| Category | Modules & Dev Boards / Function Modules |
| Reference price | Request quote |
| Min. order | 1 pcs |
| Availability | Confirm on inquiry |
| Reference stock | 0 pcs |
MUN12AD01-SG price and stock (reference)
This part is a backorder item: price and lead time are confirmed per order. Send us an RFQ and sales will reply with unit price, lead time, MOQ and in-stock alternatives.
MUN12AD01-SG specifications
| Type | Non-Isolated PoL Module |
| Number of Outputs | 1 |
| Input Voltage | 4.5V |
| Voltage - Output 1 | 0.8 ~ 6V |
| Current - Output (Max) | 1A |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, UVLO |
| Operating Temperature | -40°C ~ 85°C |
| Efficiency | 94% |
About the 1 A Non-Isolated Step-Down Power Module, 0.8-6 V Output
MUN12AD01-SG is a 6-LDFN non-isolated point-of-load module from Delta Electronics/Cyntec. The listing gives one output from 0.8 to 6 V, 1 A maximum, 94% efficiency, remote on/off, overcurrent, overtemperature and UVLO protection, a -40 to 85 C operating range and ITE commercial applications. It steps a board supply down to a local load and is not an isolated converter; it provides no galvanic isolation. The current parameter table lists a 4.5 V input value but not the complete input ceiling, so 4.5 V must not be treated as the full input range. Before production, confirm the input window, output setting method, external components, full-load temperature rise and remote on/off logic from the exact datasheet.
- Obtain the complete input range, transient margin and UVLO thresholds from the manufacturer data; the current page gives only a 4.5 V input value and cannot support a full compatibility conclusion.
- Confirm how the 0.8-6 V output is set, whether by a fixed option, external divider or another programming method, and verify the feedback and startup behaviour.
- Calculate loss, temperature rise, copper spreading and derating at 1 A, 94% efficiency and the real ambient; do not select from the headline current alone.
- Check remote on/off polarity, the unconnected state, OCP/OTP recovery and external input/output capacitors; a replacement also needs the 6-LDFN pinout checked.
MUN12AD01-SG — frequently asked questions
No. The listing identifies a non-isolated PoL module with no galvanic barrier between input and output; it is not suitable where isolation is required.
That cannot be concluded. The page does not list the complete input ceiling; 4.5 V is one recorded input value. Obtain the full input range, transient conditions and external-component requirements from the manufacturer data first.
No. Also compare input range, pinout, output-setting method, switching frequency, external components, remote on/off polarity and thermal design.